Description
Specifications:
- Voltage DC:
- Maximum voltage: 1000 V
- Accuracy: ±(0.2%+2)
- Maximum resolution: 0.001 V
- Voltage AC:
- Maximum voltage: 1000 V
- Accuracy: ±(2%+3)
- Maximum resolution: 0.1 mV
- Current DC:
- Maximum amps: 400 mA
- Amps accuracy: ±(1.0%+2)
- Maximum resolution: 0.01 mA
- Current AC:
- Maximum amps: 400 mA
- Amps accuracy: ±(2.0%+2)
- Maximum resolution: 0.01 mA
- Resistance:
- Maximum resistance: 50 MΩ
- Accuracy: ±(1.2%+2)
- maximum resolution: 0.1Ω
- Minimum test current @ 1kΩ/V: 1 mA
- Test voltages: 500, 1000 V
- Maximum resistance per test voltage:
- 50 V
- 100 V
- 250 V
- 500 V
- 1000 V: 600 MΩ
- Maximum resolution per test voltage:
- 50 V: 0.01 MΩ
- 100 V: 0.01 MΩ
- 250 V: 0.1 MΩ
- 500 V:0.1 MΩ
- 1000 V: 0.1 MΩ
- Accuracy per test voltage:
- 50 V: ±(3% + 5)
- 100 V: ±(3% + 5)
- 250 V: ±(1.5% + 5)
- 500 V: ±(2.0% + 5)
- 1000 V: ±(2.0% + 5)
- Operating temperature: –20°C to +55°C
- Storage temperature: -40°C to +60°C
- Humidity (without condensation):
- 0% – 95% (10°C – 30°C)
- 0% – 75% (30°C – 40°C)
- 0% – 40% (40°C – 55°C)
- Operating altitude: 2000 m
- Overvoltage category: Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
- Agency approvals: 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
- Battery life alkaline:
- Meter use: 1000 hours
- Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
- IP rating: IP40
- Dimensions (L x W x H): 203mm x 100mm x 50mm
- Weight 0.624kg
Warranty:
- Three Years Warranty Covered By Fluke