Fluke 1587FC Insulation Multimeter

UPC

095969796620

SKU

FLUKE1587

Fluke Co ect + Fluke’s 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily – all at a safe distance. Features:

  • Safety first. Keep yourself out of harm’s way by monitoring your test measurements remotely.
  • Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.
  • Quickly find problems by saving and comparing measurements over time on a wireless device.
  • PI/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster
  • Memory storage through Fluke Co ect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time
  • Temperature compensation to establish accurate baselines and relevant historical comparisons
  • Historical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Co ect® Assets (sold separately)
  • Provides memory storage through Fluke Co ect Measurements to eliminate the need to write down results
  • Includes live circuit detection to prevent insulation test if voltage >30 V is detected
  • Provides automated temperature compensation to establish accurate baselines
  • Supports historical tracking and asset trending of assets to identify degradation over time with Fluke Co ect® Assets (sold separately)
  • Incorporates VFD low-pass filter for accurate variable frequency motor drive measurements
  • Includes auto-discharge of capacitive voltage for added user protection
  • Measures ac/dc voltage, dc millivolts, ac/dc milliamps, resistance, and continuity
  • Includes capacitance, diode test, temperature, min/max, frequency measurements and insulation test smoothing reading
  • Automatically powers off to save battery power

$1,939.30 inc. GST

Leaves our Melbourne Warehouse in

Fluke 1587FC Insulation Multimeter

SKU FLUKE1587 Category Tag

Description

Specifications:

  • AC voltage Range – 600.0 mV:
  • Resolution: 0.1 mV
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3)
  • Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts): ±(2% + 3)
  • AC voltage Range – 6.000 V:
  • Resolution: 0.001 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3)
  • Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts): ±(2% + 3)
  • AC voltage Range – 60.00 V:
  • Resolution: 0.01 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3)
  • Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts): ±(2% + 3)
  • AC voltage Range – 600.0 V:
  • Resolution: 0.1 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3)
  • Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts): ±(2% + 3)
  • AC voltage Range – 1000 V:
  • Resolution: 1 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(2% + 3)
  • Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts): ±(2% + 3)
  • Low-Pass Filter Voltage Range 600.0 mV:
  • Resolution: 0.1 mV
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3)
  • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% – 3)
  • Low-Pass Filter Voltage Range 6.000 V:
  • Resolution: 0.001 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3)
  • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% – 3)
  • Low-Pass Filter Voltage Range 60.00 V:
  • Resolution: 0.01 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3)
  • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% – 3)
  • Low-Pass Filter Voltage Range 600.0 V:
  • Resolution: 0.1 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3)
  • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% – 3)
  • Low-Pass Filter Voltage Range 1000 V:
  • Resolution: 1 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(2% + 3)
  • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% – 3)
  • DC Voltage Measurement Range – 6.000 V dc:
  • Resolution: 0.001 V
  • Accuracy ±(% of Rdg + Counts): ±(0.09% + 2)
  • DC Voltage Measurement Range – 60.00 V dc:
  • Resolution: 0.01 V
  • Accuracy ±(% of Rdg + Counts): ±(0.09% + 2)
  • DC Voltage Measurement Range – 600.0 V dc:
  • Resolution: 0.1 V
  • Accuracy ±(% of Rdg + Counts): ±(0.09% + 2)
  • DC Voltage Measurement Range – 1000 V dc:
  • Resolution: 1 V
  • Accuracy ±(% of Rdg + Counts): ±(0.09% + 2)
  • DC Voltage Input impedance: 10 MΩ (nominal), <100 pF
  • DC Voltage Normal mode rejection ratio: >60 dB @ 50 Hz or 60 Hz
  • DC Voltage Common mode rejection ratio: >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
  • DC Millivolts Measurement Range – 600.0 mVdc:
  • Resolution: 0.1 mV
  • Accuracy ±(% of Rdg + Counts): ±(0.1% + 1)
  • DC and AC Current Measurement (AC 45 Hz to 1000 Hz):
  • Range: 400 mA
  • Resolution: 0.1 mA
  • Accuracy ±(% of Rdg+Counts): ±(1.5% + 2)¹
  • Burden voltage (Typical): 2 mV/mA
  • Range: 60 mA
  • Resolution: 0.01 mA
  • Accuracy ±(% of Rdg+Counts): ±(1.5% + 2)¹
  • Burden voltage (Typical): 2 mV/mA
  • DC Range – 400 mA:
  • Resolution: 0.1 mA
  • Accuracy ±(% of Rdg+Counts): ±(0.2% + 2)
  • Burden voltage (Typical): 2 mV/mA
  • DC Range – 60 mA:
  • Resolution: 0.01 mA
  • Accuracy ±(% of Rdg+Counts): ±(0.2% + 2)
  • Burden voltage (Typical): 2 mV/mA
  • DC Overload: 600 mA for 2 minutes maximum
  • DC Fuse protection for mA input: 0.44 mA, 1000 V, IR 10 kA
  • AC conversion: Inputs are ac-coupled and calibrated to the rms value of sine wave input
  • Ohms Measurement Range – 600.0 Ω:
  • Resolution: 0.1 Ω
  • Accuracy +(% of Rdg+Counts): ±(0.9% + 2)
  • Ohms Measurement Range – 6.000 kΩ:
  • Resolution: 0.001 kΩ
  • Accuracy +(% of Rdg+Counts): ±(0.9% + 2)
  • Ohms Measurement Range – 60.00 kΩ:
  • Resolution: 0.01 kΩ
  • Accuracy +(% of Rdg+Counts): ±(0.9% + 2)
  • Ohms Measurement Range – 600.0 kΩ:
  • Resolution: 0.1 KΩ
  • Accuracy +(% of Rdg+Counts): ±(0.9% + 2)
  • Ohms Measurement Range – 6.000 MΩ:
  • Resolution: 0.001 MΩ
  • Accuracy +(% of Rdg+Counts): ±(0.9% + 2)
  • Ohms Measurement Range – 50.0 MΩ:
  • Resolution: 0.01 MΩ
  • Accuracy +(% of Rdg+Counts): ±(1.5% + 3)
  • Ohms Overload protection: 1000 V rms or dc
  • Ohms Open circuit test voltage: <8.0 V dc
  • Short circuit current: <1.1 mA
  • Diode test indication: Display voltage drop: 0.6 V at1.0 mA nominal test current:
  • Diode Test Accuracy: ±(2% + 3)
  • Continuity Test:
  • Continuity indication: Continuous audible tone for test resistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω
  • Open circuit voltage: <8.0 V
  • Short circuit current: 1.0 mA typical
  • Overload protection: 1000 V rms
  • Response time: >1 m sec
  • Frequency Measurement Range – 99.99 Hz:
  • Resolution: 0.01 Hz
  • Accuracy ±(% of Rdg+Counts): ±(0.1% + 1)
  • Frequency Measurement Range – 999.9 Hz:
  • Resolution: 0.1 Hz
  • Accuracy ±(% of Rdg+Counts): ±(0.1% + 1)
  • Frequency Measurement Range – 9.999 kHz:
  • Resolution: 0.001 kHz
  • Accuracy ±(% of Rdg+Counts): ±(0.1% + 1)
  • Frequency Measurement Range – 99.99 kHz:
  • Resolution: 0.01 kHz
  • Accuracy ±(% of Rdg+Counts): ±(0.1% + 1)
  • Frequency Counter Sensitivity – 600.0 mV ac:
  • V ac Sensitivity (RMS Sine Wave) 5 Hz to 20 kHz: 100.0 mV
  • V ac Sensitivity (RMS Sine Wave) 20 kHz to 100 kHz: 150.0 mV
  • DC Trigger Levels to 20 kHz: NA
  • Frequency Counter Sensitivity – 6.0 V:
  • V ac Sensitivity (RMS Sine Wave) 5 Hz to 20 kHz: 1.0 V
  • V ac Sensitivity (RMS Sine Wave) 20 kHz to 100 kHz: 1.5 V
  • DC Trigger Levels to 20 kHz: -400.0 mV and 2.5 V
  • Frequency Counter Sensitivity – 60.0 V:
  • V ac Sensitivity (RMS Sine Wave) 5 Hz to 20 kHz: 10.0 V
  • V ac Sensitivity (RMS Sine Wave) 20 kHz to 100 kHz: 36.0 V
  • DC Trigger Levels to 20 kHz: 1.2 V and 4.0 V
  • Frequency Counter Sensitivity – 600.0 V:
  • V ac Sensitivity (RMS Sine Wave) 5 Hz to 20 kHz: 100.0 V
  • V ac Sensitivity (RMS Sine Wave) 20 kHz to 100 kHz: –
  • DC Trigger Levels to 20 kHz: 12.0 V and 40.0 V
  • Frequency Counter Sensitivity – 1000.0 V:
  • V ac Sensitivity (RMS Sine Wave) 5 Hz to 20 kHz: 300.0 V
  • V ac Sensitivity (RMS Sine Wave) 20 kHz to 100 kHz: –
  • DC Trigger Levels to 20 kHz: 12.0 V and 40.0 V
  • Capacitance Range 1000 nF:
  • Resolution: 1nF
  • Accuracy ±(% of Rdg+Counts): ±(1.2% + 2)
  • Capacitance Range 10.00 μF
  • Resolution: 0.01 μF
  • Accuracy ±(% of Rdg+Counts): ±(1.2% + 2)
  • Capacitance Range 100.0 μF
  • Resolution:0.1 μF
  • Accuracy ±(% of Rdg+Counts): ±(1.2% ±90 counts)
  • Capacitance Range 9999 μF
  • Resolution:1 μF
  • Accuracy ±(% of Rdg+Counts): ±(1.2% ±90 counts)
  • Temperature Measurement Range -40°C to 537°C:
  • Resolution: 0.1 °C
  • Accuracy ±(% of Rdg+Counts): ±(1% + 10 counts)
  • Temperature Measurement Range -40°F to 998°F:
  • Resolution: 0.1 °F
  • Accuracy ±(% of Rdg+Counts): ±(1% + 18 counts)
  • Insulation Specifications:
  • Measurement range: 0.01 MΩ to 2 GΩ
  • Test voltages: 50, 100, 250, 500, 1000 V
  • Test voltage accuracy: +20%, -0%
  • Short-circuit test current: 1 mA nominal
  • Auto discharge: Discharge time <0.5 second for C = 1 μF or less
  • Live circuit detection: Inhibit test if terminal voltage > 30 V prior to initialization of test
  • Maximum capacitive load: Operable with up to 1 μF load
  • Output Voltage 50 V (0% to +20%):
  • Display range: 0.01 to 6.00 MΩ
  • Resolution: 0.01 MΩ
  • Test current: 1 mA @ 50 kΩ
  • Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
  • Display range: 6.0 to 50.0 MΩ
  • Resolution: 0.1 MΩ
  • Test current: 1 mA @ 50 kΩ
  • Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
  • Output Voltage 100 V (0% to +20%):
  • Display range: 0.01 to 6.00 MΩ
  • Resolution: 0.01 MΩ
  • Test current: 1 mA @ 100 kΩ
  • Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
  • Display range: 6.0 to 60.0 MΩ
  • Resolution: 0.1 MΩ
  • Test current: 1 mA @ 100 kΩ
  • Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
  • Display range: 60 to 100 MΩ
  • Resolution: 1 MΩ
  • Test current: 1 mA @ 100 kΩ
  • Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
  • Output Voltage 250 V (0% to +20%):
  • Display range: 0.1 to 60.0 MΩ
  • Resolution: 0.1 MΩ
  • Test current: 1 mA @ 250 kΩ
  • Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
  • Display range 60 to 250 MΩ
  • Resolution 1 MΩ
  • Test current 1 mA @ 250 kΩ
  • Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
  • Output Voltage 500 V (0% to +20%):
  • Display range:0.1 to 60.0 MΩ
  • Resolution: 0.1 MΩ
  • Test current: 1 mA @ 500 kΩ
  • Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
  • Display range: 60 to 500 MΩ
  • Resolution: 1 MΩ
  • Test current: 1 mA @ 500 kΩ
  • Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
  • Output Voltage 1000 V (0% to +20%):
  • Display range:0.1 to 60.0 MΩ
  • Resolution: 0.1 MΩ
  • Test current: 1 mA @ 1 MΩ
  • Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
  • Display range: 60 to 600 MΩ
  • Resolution: 1 MΩ
  • Test current: 1 mA @ 1 MΩ
  • Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
  • Display range: 0.6 to 2.0 GΩ
  • Resolution: 100 MΩ
  • Test current: 1 mA @ 1 MΩ
  • Resistance accuracy ±(% of Rdg + Counts): ±(10% + 3 counts)
  • Maximum voltage applied to any terminal and common: 1000 V
  • Storage temperature: -40 °C to 60 °C (-40 °F to 140 °F)
  • Operating temperature: -20 °C to 55 °C (-4 °F to 131 °F)
  • Temperature coefficient: 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
  • Relative humidity:
  • Noncondensing
  • 0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)
  • 0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)
  • 0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)
  • Vibration: Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
  • Radio frequency communication: 2.4 GHz ISM Band
  • Radio frequency certification: FCC: T68-FBLE, IC: 6627A-FBLE
  • IEC 61010-1: Pollution Degree 2
  • IEC 61010-2-033: CAT IV 600 V / CAT III 1000 V
  • Batteries: 4 x AA batteries (NEDA 15A or IEC LR6)
  • Battery life: Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
  • Operating Altitude: 2000 m
  • Storage Altitude: 12,000 m
  • Over-range capability: 110% of range except for capacitance which is 100%
  • Frequency overload protection: <107 V Hz
  • Fuse protection for mA input: 0.44A, 1000 V, IR 10 kA
  • Dimensions (L x W x H): 203mm x 100mm x 50mm
  • Weight 0.55kg

Warranty:

  • Three Years Warranty Covered By Fluke

Brand

Fluke

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals — people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.

Fluke has achieved the number one or number two position in every market in which it competes. The Fluke brand has a reputation for portability, ruggedness, safety, ease of use and rigid standards of quality.

electrician tools

Additional information

Weight .8 g
Dimensions 30 × 20 × 10 mm

Specifications

.

Have no product in the cart!
0