Specifications:
- Basic DC accuracy: 0.09%
- Bandwidth: 1% 45 Hz to 65 Hz, full time low pass filter
- Voltage: AC/DC 1000 V
- Current AC: 2500 A with included iFlex Flexible Current Probe
- Resistance: 50 MΩ
- Frequency: 100 kHz
- Capacitance: 9,999 µF
- Continuity with beeper: Yes
- Diode test: Yes
- Min/Max recording: Yes
- Display Hold: Yes
- Infrared resolution: 102 x 77
- Image capture frequency: 8 Hz
- Field of View: 36° (w) x 27° (h)
- NETD: ≤200 mK
- Infrared spectral band: 7.5 to 14 microns
- Center point: Yes (with center point temp)
- Focus mechanism: Fixed focus
- Temperature Range (selectable °C and °F): -10 °C to 200 °C (14 °F to 392 °F)
- Accuracy: ±5 °C (9 °F) or (±5% as tested)
- Emissivity: 0.95 fixed
- Background compensation: 20 °C fixed
- Memory storage: Approximately 100 images (internal)
- File format: Non-radiometric .is2
- Battery type: Rechargeable lithium ion battery (charge time: 4.5 hours)
- Operating temperature: -10 °C to 50 °C (14 °F to 122 °F)
- Storage temperature: -20 ºC to 60 ºC (-4 °F to 140 °F)
- Relative humidity:
- 0% to 90% (0 °C to 35 °C) (32 °F to 95 °F)
- 0% to 75% (35 °C to 40 °C) (95 °F to 104 °F)
- 0% to 45% (40 °C to 50 °C) (104 °F to 122 °F)
- Altitude: 2,000 meters (6,561 feet)
- Temperature coefficient: Add 0.1 x specified accuracy for each °C above 28 °C or below 18 °C (°F above 82 °F or below 64° F)
- Ingress Protection: IP40 (non-operating)
- Wireless frequency: 2.4 GHz ISM Band, 20 meter range
- Certifications: CE, CSA, FCC
- Safety compliance: IEC 61010-1: Pollution degree 2; IEC 61010-2-033: CAT III 1000 V/CAT IV 600 V
- EMC: EN 61326-1:2012
- Dimensions (L x W x H): 215.9mm x 93.9mm x 57.1mm
- Weight 0.793kg
Warranty:
- Three Years Limited Warranty Covered By Fluke