Specifications:
- Voltage DC:
- Range: 6.000 V – 1000 V
- Best accuracy: ±(0.3% + 1)
- Best resolution: 0.1 mV
- Voltage AC:
- Range: 600.0 mV – 1000V
- Best accuracy: ±(2.0% + 2)
- Best resolution: 1.0 mV
- Amps AC:
- Range: 60.00 mA – 10 A
- Best accuracy: 2.5% + 2
- Best resolution: 0.01 mA
- Amps DC:
- Range: 60.00 mA – 10A
- Best accuracy: 1.5% + 2
- Best resolution: 0.01 mA
- Resistance:
- Range: 600.0 Ω – 50 MΩ
- Best accuracy: ±(0.5% + 1)
- Best resolution: 0.1 Ω
- Capacitance:
- Range: 1nF – 9,999 μF
- Best accuracy: ±(1.2% + 2)
- Best resolution: 1 nF
- Frequency:
- Range: 99.99Hz – 99.99kHz
- Best accuracy: ±(0.1% + 1)
- Best resolution: 0.01 Hz
- Safety: ANSI / ISA S82.02.01, CSA C22.2–1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV
- Certifications: CSA, TÜV (EN61010), Π, (N10140)
- Maximum voltage between any terminal and earth ground: 1000 V
- Surge protection: 8 kV peak per IEC 61010
- Ω Fuse for mA inputs: 440 mA, 1000 V FAST Fuse
- Ω Fuse for A inputs: 11 A, 1000 V FAST Fuse
- Display:
- Digital: 6000 counts, updates 4/sec
- Bar graph: 33 segments, updates 32/sec
- Frequency: 10,000 counts
- Capacitance: 1,000 counts
- Operating Altitude: 2,000 meters
- Storage Altitude: 12,000 meters
- Operating Temperature: -10°C to + 50°C
- Storage Temperature: -40°C to + 60°C
- Temperature coefficient: 0.1 x (specified accuracy / °C (< 18°C or > 28°C)
- Electromagnetic compatibility: (EN 61326–1:1997) In an RF field of 3 V/M, accuracy = specified accuracy except in temperature:
- specified accuracy ±5°C (9°F)
- Relative humidity (maximum non-condensing):
- 90% to 35°C
- 75% to 40°C
- 45% to 50°C
- Battery life: 400 hours typical (alkaline)
- Dimensions (L x W x H): 185mm x 90mm x 43mm
- Weight 0.420kg
Warranty:
- Limited Lifetime Warranty Covered By Fluke